Smart Pesticides Database - Funzionalità

Database for GC-MS and GC-MS/MS

Supports the Simultaneous Analysis of 530 Residual Pesticides in Foods via GC-MS(/MS)

 

Smart Pesticides Database contains the retention indices and transitions for 530 pesticides. Ver. 2 additionally contains measurement ions for SIM mode, so it can be applied to both SIM and MRM analyses.
Thanks to the retention indices contained in the database and the AART function, retention times can be revised automatically without the use of pesticide standards.
Furthermore, the Smart MRM™/SIM function allows the automatic creation of the optimal measurement programs for multicomponent simultaneous analysis using MRM and SIM modes.
Lastly, the database can be customized to the GC conditions and the addition of new components.

 

Supports the Simultaneous Analysis of 530 Residual Pesticides in Foods via GC-MS(/MS)

Enables Analysis Conditions Corresponding to a Variety of Needs

Supporting simultaneous multicomponent, high-speed analysis, the database can enable a choice of methods according to the usage.
In addition, the database contains retention indices for multiple columns with different polarities. As a result, even if peaks of target pesticides and contaminants overlap it can use a different column.
If the database is used in combination with the Twin Line MS system, analysis with different columns can be performed smoothly, without compromising the MS vacuum.

Provides Total Solution Including Certified Standard Substances, a Pretreatment Kit, and Consumables

If used in combination with the recommended Certified standard substances, pretreatment kit, columns, and insert liners, the database enables high-accuracy pesticide analysis.
The recommended pretreatment kit and the recommended protocol can be applied even to high-matrix samples such as health foods and processed foods.

Verifying the Effectiveness of Recovery Tests of Health Foods



  • In conducting recovery tests in health foods for 220 pesticides, using the database, recommended pretreatment kit, pretreatment protocol, and Certified standard substances, we succeeded in obtaining excellent ratios in over 80 percent of components.

    Health foods contain many contaminants. Because it includes transitions for the separation of contaminants, the database minimizes their impact.

    Additionally, the database can separate contaminants by allowing analysis with a different column, even if peaks of target pesticides and contaminants overlap. If the database is used in combination with the Twin Line MS system, analysis with different columns can be performed smoothly, without compromising the MS vacuum.
  • Distribution of rates for two health food samples which were spiked with a pesticide standard sample so as to obtain a nal concentration of 2.5 ng/mL each.
    Distribution of rates for two health food samples which were spiked
    with a pesticide standard sample so as to obtain a final concentration
    of 2.5 ng/mL each.

 

 

A printed handbook of the pretreatment protocol

  • A printed handbook of the recommended pretreatment protocol is provided (C146-E333), allowing customers to try the pretreatment process with ease.
 

Twin Line MS System

  • Analysis can be performed smoothly on different columns without interrupting the MS vacuum by simultaneously attaching the mass spectrometer to the outlets of two different columns installed in two separate injection units.
  • Twin Line MS System

 

 

 